Regency L676E-LP Indoor Fireplace User Manual


 
Regency
®
L676E Direct Vent Gas Fireplace
18
INSTALLATION
L676 & L900 Direct Vent Fireplace
IMPORTANT NOTE
A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower.
The Simpson Dura-Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any applications.
Only the AstroCap XL and Snorkels are certifi ed for horizontal terminations.
NOTE: Horizontal runs of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards
the termination. Never allow the vent to run downward. This could cause high temperatures and
may present a possible fi re hazard.
Offset Pipe Selection:
Use this table to determine offset pipe lengths.
Pipe Length
5” x 8” Venting
Run (X) Rise (Y)
0”(0mm) 5-11/16”(144mm) 15-5/16”(389mm)
6”(152mm) 8-13/16”(224mm) 18-7/16”(468mm)
9”(229mm) 10-15/16”(278mm) 20-9/16”(522mm)
12”(305mm) 13”(330mm) 22-11/16”(576mm)
24”(610mm) 21-7/16”(697mm) 31-1/16”(789mm)
36”(914mm) 29-13/16”(757mm) 39-7/16”(1002mm)
48”(1219mm) 38-1/4”(972mm) 47-7/8”(1216mm)
L
Y
X
FPI
946-604/P Simpson Direct Vent Vent Guard (Optional) 946-623/P AstroCap XL Horizontal Cap
770-994 Rigid Pipe Adapter (Must use with all Rigid Piping) 946-506/P Vent Guard (Optional)
946-625 Vinyl Siding Standoff - AstroCap XL
Description
Simpson
Direct Vent Pro
®
Simpson
Direct Vent GS
®
Discontinued
Selkirk
Direct-Temp™
Metal-Fab
®
Sure Seal
Round Support / Radiation Sheild N/A N/A N/A N/A
Flat Flashing N/A N/A N/A N/A
Attic Insulation Shield 12” 58DVA-IS - N/A from FPI 58DVA-IS - N/A from FPI N/A N/A
Basic Horizontal Termination Kit (A) N/A N/A 5DT-HKA N/A
Horizontal Termination Kit (B) 58DVA-KHA N/A 5DT-HKB N/A
Vertical Termination Kit 58DVA-VCH 1291 5DT-VKC N/A
High Wind Vertical Cap N/A N/A N/A N/A
High Wind Horizontal Cap DISC. 1285 N/A N/A
Horizontal Square Termination Cap N/A 1284 5DT-HHC 5DHT
Vertical Termination Cap N/A N/A 5DT-HVC 5DVT
Storm Collar 58DVA-SC 1253 5DT-SC 5DSC
Adjustable Flashing, 0/12-6/12 58DVA-F6 1243 5DT-AF6 5DF
Adjustable Flashing, 6/12-12/12 58DVA-F12 1243S 5DT-AF12 5DF-12
Vinyl Siding Standoff 58DVA-VSS 1250 5DT-VS 5DVS
Vinyl Siding Shield Plate N/A N/A 5DT-VSP N/A
Snorkel Termination 14” 58DVA-SNK14 1282 5DT-ST14 5DST14
Snorkel Termination 36” N/A 1281 5DT-ST36 5DST36
Restrictor Disk 58DVA-RD N/A N/A N/A
Colinear Flex Liner Adapter (3” Ø) N/A N/A N/A N/A
Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.
*NOTE: When using Metal-Fab Sure Seal Rigid Piping please note that either the Adaptor (5DDA) or 90º Starter Elbow
(5D90A) must be used in conjunction with FPI Rigid Pipe Adaptor (770-994).
For specifi c instructions or details on particular
venting components please visit the following
websites:
Simpson Direct Vent Pro: www.duravent.com
Selkirk Direct-Temp: www.selkirkcorp.com
Metal-Fab Sure Seal: www.mtlfab.com
INSTALLATION