Regency L676E-LP Indoor Fireplace User Manual


 
Regency
®
L676E Direct Vent Gas Fireplace
16
INSTALLATION
RIGID PIPE VENTING SYSTEMS
BASIC HORIZONTAL & VERTICAL TERMINATIONS
Rigid Pipe Vent Systems offer a complete
line of component parts for installation of both
horizontal and vertical installations. Many items
are offered in decorative black, as well as gal-
vanized fi nish.
The minimum components required for a basic
horizontal termination are:
1 Horizontal Termination Cap
1 90
o
Elbow
1 Rigid Pipe Adaptor
1 Wall Thimble
1 Length of pipe to suit wall thickness
The minimum components required for a basic
vertical termination are:
1 Vertical Termination Cap
1 Rigid Pipe Adaptor
1 Lengths of pipe to adequately
penetrate roof
1 Ceiling Firestop
1 Flashing
1 Storm Collar
Wall thickness is measured from the back
standoffs to the inside mounting surface of
termination cap. For siding other than vinyl
furring strips may be used, instead of the vinyl
siding standoff, to create a level surface to
mount the vent terminal. The Terminal must
not be recessed into siding. Measure the wall
thickness including furring strips.
If a Vinyl Siding Standoff is required (it must
be used with vinyl siding), measure to outside
surface of wall without siding and add 2
inches.
Alternate
Horizontal Termination
Caps
The FPI AstroCap XL
TM
is certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent
®
Direct Vent GS and Selkirk Direct-Temp.
AstroCap XL
TM
is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary
trademarks of Simpson Dura-Vent Co. Inc.
INSTALLATION
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be
used to secure rigid pipe to adaptor.
This product has been evaluated by Intertek for
using a Rigid Pipe Adaptor in conjunction with
Duravent Direct-Vent GS and Selkirk Direct-
Temp systems. Use of these systems with
the Rigid Pipe adaptor is deemed acceptable
and does not affect the Intertek WHI listing of
components.
WARNING:
Do not combine venting components from
different venting systems.
Use of the the AstroCap XL
TM
is acceptable
with all systems.
IMPORTANT NOTE
• The Simpson Dura-Vent and Selkirk Direct
Temp horizontal termination caps cannot
be used in any applications.
• Only the AstroCap XL and Snorkels are
certifi ed for horizontal terminations.
* A Vent Guard is required when the AstroCap
is installed above grade at 7 feet or lower.