30
INSTALLATION
LOG SET INSTALLATION
Installation of Interior Brick Panels must be completed before installing the log set.
INSTALLATION
Read the instructions below carefully and refer to the diagrams.
If the logs are broken do not use the unit until they are replaced.
Broken logs can interfere with pilot operation.
Log kit (Part No. 521-930 and 521-935) contain the following pieces:
a) 03-25 Log Rear
b) 03-26 Log Top
c) 03-27 Log Front Left
d) 03-28 Log Front Right
e) 902-154 Embers Lava
f) 902-179 Vermiculite
g) 946-669 Platinum Embers (supplied with packaged manual)
1) Carefully remove the logs from the box and unwrap them. The logs
are fragile, handle with care - do not force into position.
2) Place log 03-25 on the rear log support pins.
The "03" reference numbers (i.e. 03-25) are
molded into the rear of each log.
3) Place log 03-27 on the front left side of the burner. Place the right
end of the log into the pin and rest the left end of the log inbetween
the rear and front burner tubes.
03-28
03-26
03-27
03-25
03-25
03-27
4) Place the left end of log 03-28 into the pin while resting the right end
of the log on the grate. Slide the right end of the log forward until it
is approximately 3/8" away from the back side of the grate.
03-28
Rear
Burner
Tube
Front Burner Tube
Backside of Grate
5) Line up the two holes on the underside of log 03-26 with the pins on
logs 03-25 and 03-27 and fi t in place.
03-26
03-27
03-25