All electrical work must conform to local codes as well as the National Electrical Code, ANSI/
NFPA70, latest revision. In Canada, electrical wiring shall comply with the Canadian Electrical
Codes, CSAC22.1 and .2
A. ELECTRIC POWER SUPPLY
Prior to making any line voltage connections, service switch at boiler should be in the off
position and the power turned off at the fuse box
Run a separate 120 volt circuit from a sperate over current protection device in the
electrical service entrance panel. This should be a 15 ampere circuit. A service switch has
been pre-wired and located on the exterior boiler jacket. See Fig. 13 for diagram showing
location of service switch junction box and power supply connection points. Connect black
(hot) lead from the power supply
FIGURE 12 GAS PIPING
The length of pipe or tubing should be measured from the gas meter or propane second stage regulator.
WARNING
TURN OFF ELECTRICAL POWER AT FUSE BOX BEFORE MAKING ANY LINE
VOLTAGE CONNECTIONS. FOLLOW LOCAL ELECTRICAL CODES.
ELECTRICAL WIRING