Quadra-Fire DV-40 Indoor Fireplace User Manual


 
Page 34
CONVERSION INSTRUCTIONS (CONT.)
Pilot Tower Orifice Replacement
13. Loosen (CCW rotation) and remove pilot target hex fitting with a 7/16 end wrench as shown in figure
A.
FIG. A
14. Remove the currently installed orifice with a pair of needlenose pliers or other means as shown in
figure B.
FIG. B
15. Install the conversion orifice.
16. Reinstall the pilot target hex fitting and tighten it until the index marks align with each other as shown
in figure C.
FIG. C
17. Reinstall left burner pan top plate. (Reverse steps 8 & 9)
18. Reinstall center burner pan top plate.
19. Reinstall rear burner by slipping burner end over orifice receiver and snapping into pinch brackets.
20. Reinstall U burner by slipping through shutter ring and over orifice receiver and snapping into pinch
bracket.
21. Orifice sizes for the pilot are as follows:
NG=.026/.023 LP=.026/.016
Log replacement
22. Reinstall in reverse order of steps 5-7.
23. Install nuggets and top logs as instructed on page 35-37 of this manual.