Page 21
HORIZONTAL INSTALLATION (CONT.)
Step 5. Before connecting the horizontal run of vent pipe to the vent termination, slide the black decorative
wall thimble cover over the vent pipe.
Step 6. Slide the stove and vent assembly towards the wall, carefully inserting the vent pipe into the vent
cap assembly. It is important that the vent pipe extend into the vent cap sufficient distance so as
to result in a minimum pipe overlap of 1¼” (32mm). Secure the connection between the vent
pipe and the vent cap by attaching the two sheet metal strips extending from the vent cap assembly
into the outer wall of the vent pipe. Use the two sheet metal screws provided to connect the strips
to the pipe section. Bend any remaining portion of the sheet metal strip back towards the vent
cap, so it will be concealed by the decorative wall thimble cover (Figure 9).
Note: The attachment from the vent pipe to the vent cap must be siliconed.
Step 7. Slide the decorative wall thimble up to the wall surface and attach with screws provided.
(Figure 10). Apply decorative brass or chrome trim if desired.
ddesireddesired.
FIG. 9
FIG. 10