Page26
October 27, 2011
R
Castile & Santa Fe CE Insert
7069-101B
8
Venting Systems
Figure 28.1
CAUTION
Neverdrawoutsidecombustionairfrom:
• Wall,oororceilingcavity
• Enclosedspacesuchasanatticorgarage
NOTE:
• IllustrationsreecttypicalinstallationsandareFOR
DESIGNPURPOSESONLY.
•Illustrations/diagramsarenotdrawntoscale.
• Actualinstallationmayvaryduetoindividualdesign
preference.
A. Full Reline With Horizontal Outside Air
Outside Air through Rear
Wall (Horizontal)
NOTE; Use metal plate around
exhaust vent pipe and seal all
edges with non-flammable insu-
lation such as , mineral wool or
ceramic.
Do not use high temperature
caulking materials to seal any
edge to prevent future service-
ability.
FireRisk.
InspectionofChimney:
• Masonrychimneymustbeingoodcondition.
• MeetsminimumstandardofNFPA211
•
Factory-builtchimneymustbeaminimum152mm
UL103HT.
WARNING
Outside Air through Rear
Wall (Horizontal)
NOTE; Use metal plate around
exhaust vent pipe and seal all
edges with non-flammable insu-
lation such as fiberglass, mineral
wool or ceramic.
Do not use high temperature
caulking materials to seal any
edge to prevent furture service-
ability.
Figure 28.2