R
October 27, 2011
Page21
Castile & Santa Fe CE Insert
7069-101B
Figure 20.4 - Top View
A
B
C
D
C. Minimum Opening for Masonry and
Factory-Built Fireplaces
Inches Millimeters
A
Insertsidetocombustiblesidewall 16 406
B
Inserttoptomantel 12 305
C
Inserttoptomaximum.2-1/4inch
(57mm)facetrim
4-3/4 121
D
Insertsidetomaximum.2-1/4inch
(57mm)facetrim
10 254
Location Millimeters (Castile/Santa Fe)
A
RearWidth 600/610
B Depth 432/406
C Height 540/591
D FrontWidth 714/743
Figure 22.1
B. Masonry and Factory-Built Fireplaces *
(Shown on a CASTILE INSERT)
Inches Millimeters
E
Floorprotectionhearthextensionfrom
dooropening
6 152
F
Floorprotectiontothesideofdoor
opening
6 152
D. Floor Protection
Figure 22.2
Side Wall
Mantel
Maximum Mantel Depth: 12 inches (305mm)
Face
Trim
E
F
A
D
C
B
E. Prefabricated Metal Chimney
Thechimneycanbeneworexisting,masonryorprefabricated
andmustmeetthefollowingminimumrequirements:
•Mustbeminimum 152mminsidediameterofhigh
temperaturechimneylistedtoUL103HT(2100
o
F).
•Mustusecomponentsrequiredbythemanufacturerfor
installation.
•Mustmaintainclearancesrequiredbythemanufacturer
forinstallation.
•Refertomanufacturersinstructionsforinstallation
•ThisinsertislistedtoUL1482Standardandisapproved
forinstallationintolistedfactory-builtzero
clearancere-
placeslistedtoUL127conformingtothefollowingspeci-
cationsandinstructions:
•The original factory-built clearance replace chimney
cap must be re-installed after installing the approved
chimney liner meeting type UL 103 HT requirements
(2100°F)perUL1777.
•IfthechimneyisnotlistedasmeetingHTrequirements,
orifthefactorybuiltreplacewastestedpriorto1998,a
fullheightlistedchimneylinermustbeinstalledfromthe
applianceuecollartothechimneytop.
•Thelinermustbesecurelyattachedtotheinsertuecollar
andthechimneytop.
•Theairowofthefactory-builtzero-clearancereplace
systemmustnotbealtered.Theuelinertopsupport
attachmentmustnotreducetheairowfortheexisting
air-cooledchimneysystem.
•Nodilutionairisallowedtoenterthechimney.
1.Securethereplacedamperintheopenposition.If
thiscannotbeaccomplished,itwillbenecessaryto
removethedamper.t
2.Seal damperareaofchimneyaroundchimney
connectorwithahightemperaturesealantorseal
insertagainstthefaceofthereplace.
3.Bothmethodsmustberemovableandreplaceable
forcleaningandre-installation.
* the Castile and Santa Fe inserts are only intended
for installation into a masonry or factory built re-
place