Quadra-Fire CASTILEI-CE-MBK Indoor Fireplace User Manual


 
Page24
October 27, 2011
R
Castile & Santa Fe CE Insert
7069-101B
E. Chimney and Exhaust Connection
1. Chimney & Connector:Use76mmto102mmdiameter
type"L"or"PL"ventingsystem.Itcanbeventedvertically
orhorizontally.
2. Residential: Use24gaugesinglewallueconnectoror
ListeddoublewallueconnectortoClassAListedmetal
chimneys,ormasonrychimneysmeetingInternationalBuild-
ingCode(ICC)standardsforsolidfuelappliances.4.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER.
4. Exhaust VentingSystem:Securetotheappliancewith
atleast2screws180degreesapart.Alsosecureallcon-
nectorpipejointswithatleast3screwsthrougheachjoint.
5. DONOTINSTALLAFLUEDAMPERINTHEEXHAUST
VENTINGSYSTEMOFTHISUNIT.
6. DONOTCONNECTTHISUNITTOACHIMNEYFLUE
SERVINGANOTHERAPPLIANCE.
NOTE: All pipe must be welded seam pipe whenever pos-
sible. Seal pipe joints with high temperature silicone (260°C)
minimum rated only. Do not put silicone inside of pipe.
VentsurfacesgetHOT,cancauseburnsif
touched.Non-combustibleshieldingorguards
mayberequired.
WARNING
WARNING
ONLYuseconnector:
• Withintheroom,betweenapplianceandceilingorwall.
ConnectorshallNOTpassthrough:
• Atticorroofspace
• Closetorsimilarconcealedspace
• Floororceiling
Maintainminimumclearancestocombustibles
Fire Risk.
FollowChimneyConnectorManufacturer’s
InstructionsforProperInstallation.
CAUTION
• DONOTCONNECTTHISUNITTOACHIMNEYFLUE
SERVICINGANOTHERAPPLIANCE.
• DONOTCONNECTTOANYAIRDISTRIBUTIONDUCT
ORSYSTEM.
Mayallowuegasestoenterthehouse