A. GENERAL
1. Pinnacle boilers are to be installed in an area with a
floor drain or in a suitable drain pan. Do not install
any boiler where leaks or relief valve discharge will
cause property damage.
2. This boiler is not intended to support external piping.
All venting and other piping should be supported
independently of the boiler.
3. Install this boiler level to prevent condensate from
backing up inside the boiler.
B. WALL HUNG BOILERS
1. The PI-T50 and PI-T80 Boilers are provided with
slots for wall mounting and feet for floor mounting.
Refer to Figure 10.1 in this manual for dimensions &
locations.
2. If wall mounted, the boiler must be attached to a
wall that provides adequate support for the boiler.
3. Use a minimum of 1/4" threaded fasteners for
supporting the boiler. Do not mount the boiler to
wall board only.
4. Be sure to adequately support the boiler while
installing external piping. Be sure to pipe condensate
to a suitable drain or condensate pump.
C. FLOOR MOUNTED BOILERS
1. PI-80, PI-140, and PI-199 boilers are designed for
floor mounting. The PI-80 can be wall mounted
using the optional boiler stand available through
your PB Heat, LLC distributor (Part Number 91439).
2. The boiler stand may used for floor mounting of the
PI-140 and PI-199 boilers.
2. BOILER SET-UP
BOILER SET-UP
This boiler is must be installed level to prevent
condensate from backing up inside the boiler.
CAUTION
Make sure the boiler is adequately supported. Do not
install this boiler on drywall unless adequately
supported by wall studs.
WARNING