36
(1)
(4) Soft Tapping
(2)
(3)
ABOUT THE BODY SCANNING FUNCTION
Body Scanning
(1) As the electronic tone that accompanies the body search function sounds,
the massage heads will rise up the back until they reach the area behind
the neck.
(2) The massage heads will tilt forward so that they are positioned over the
shoulders. (If the shoulder position is incorrect the massage heads will
rise again and then repeat the shoulder alignment movement.)
(3) The massage heads will descend to the level of the shoulders.
(4) A soft tapping massage is performed at the level of the shoulders, which
lasts for approximately 15 seconds.
Additional Information
Pressure Feedback Function
The strength of the massage (pressure level) is automatically adjusted if it is too much or too little.
• The standard body pressure level varies according to the strength of the program selected.
• If you lift your back or stand up in the middle of a massage, the body pressure level detected will be zero
thus causing the massage to finish.
Pressure Feedback in Shoulder Area
• When a massage program is used, the body pressure level at the top of the shoulders is detected just
before the start of a massage at the top of the shoulders. If the body pressure level is different from that of
the previous massage a soft tapping massage will begin.
When the Body Scanning Function is Not Completed Successfully
• A recorded voice message will announce, “In the interests of safety, the massage will now finish because
an occupant could not be detected in the chair.” during the body scanning.
This may occur in the following situations:
1. Pressure against the backrest cannot be detected because no one is sitting in the chair.
2. Pressure against the backrest cannot be detected because the occupant’s head and back are not
touching the backrest.
3. Pressure against the backrest cannot be detected because the occupant is wearing heavy clothing or an
object such as a cushion has been placed between the occupant’s back and the backrest.
Sit as far back in the seat with your head on the pillow and
press again to start the body scanning.
When the Soft Tapping Massage Does Not Start
• If the body scanning is performed at the highest height, it will stop for a few seconds and the soft tapping
massage will not be carried out.
To adjust the shoulder position, do so after the massage has begun.
When Changing the Occupant in the Middle of a Massage
• Press once to finish the massage then start again as the shoulder position will change.
Additional Information