Figure 3-11. Closing the Stator Figure 3-12. Adjusting the Clamp Screw
1. Refer to Figure 3-8 and Figure 3-9. Snap open the Stator by pushing the
spring-loaded area of the Latch. Remove any old tubing from the pump, if
necessary.
2. Refer to Figure 3-8 and Figure 3-10. Loop the Tubing over the rollers. This is
easy to do even for stacked pumps.
Tubing can be changed on stacked pumps without detaching either of the
pumps from the motor.
3. Refer to Figure 3-11. Push the Stator closed until you hear the Latch engage.
4. Refer to Figure 3-12. Tighten the Clamp Screw until the Clamp Plate contacts
the Tubing, securing it in place.
5. Set up the source and drain containers so that the tubing inlet is immersed in the
fluid in the source container and the tubing outlet is in the drain container.
See Section 5.2 to set the pumping direction.