Omega Speaker Systems FPU5-MT-220 Water System User Manual


 
Getting Started
3
3-2
3.1.2 Attaching a Single Pump Directly to the Motor
Perform ALL of the steps in Chapter 3 before turning the motor on.
Refer to Figures 3-1 through 3-4.
Figure 3-1. Pump in Closed Position Figure 3-2. Aligning the Rotor Shaft
Figure 3-3. Pump in Closed Position Figure 3-4. Aligning the Rotor Shaft
1. Remove the safety cover if it is on the side of the motor you wish to use. If you
are using one side of the motor only, attach the safety cover to the other side.
2. Refer to Figure 3-1. Make sure the pump is in the closed position.
3. Refer to Figure 3-2. Place the blade of a flathead screwdriver in the groove of
the Rotor Shaft. Rotate the Rotor Shaft until its back tab slips into the groove of
the motor shaft. Do not try to force the pump onto the motor until you perform
Step #4.
4. Refer to Figure 3-3. Swivel the pump back and forth slightly to align the holes
on the back of the Base with the alignment pins on the face of the motor. Press
the pump base up against the face of the motor.
FACE OF
MOTOR
STANDARD
MOUNTING
SCREWS
FACE OF
MOTOR
TOP ALIGNMENT
PIN
BOTTOM
ALIGNMENT PIN
ROTOR SHAFT
FLAT HEAD
SCREWDRIVER
MOUNTING
HOLES
MOTOR
SHAFT
Base
Rotor
Shaft
CAUTION