Chapter 10 Electronic Gearing and Camming
© National Instruments Corporation 10-11 NI-Motion User Manual
Algorithm
Similar to gearing, in a camming application, a slave axis can perform any
move when camming is enabled. The move profile is superimposed over
the camming profile.
Figure 10-8. Camming Algorithm
Set the Master Cycle
Load Move Constraints
Set Operation Mode
Load Target Position
Start Motion on Slave Axis
Enable Camming
Camming
Superimposed
Straight-line Move
(optional)
Designate a Master
Camming Device
The device can be one of the following:
an axis
an encoder
an analog sensor
The slave axis now moves in
proportion to the master device.
Configure the Buffer
for Slave Positions
Load the Slave Positions
to the Cam Table
Set the Master and
Slave Offset (optional)