Napco Security Technologies F-64TPBR Home Security System User Manual


 
20
to the right.
2. Repeat this process to increment (or decrement) the minute as needed. Press EN-
TER move the cursor to the right and press the YES or NO buttons to toggle between
"A" and "P" (for AM and PM). When finished, press MENU to save and proceed to
the next option, "ENROLL MASTER I-FOB Y/N".
Create Master I-FOB
The I-FOB is a uniquely coded digital key that performs the following functions when
inserted into the Touchpad I-FOB slot:
Disarm an armed system
Silence an active alarm
Reset a fire alarm
The Master I-FOB supplied with your system also allows access to additional features
within the Touchpad Menu Mode (see page 15), including access to this User Program
Mode. Note: Only one Master I-FOB can exist within the system. Because the Master I-
FOB must be used to enter this User Program Mode menu, this option "Create Master I-
FOB" is included in case your existing Master I-FOB--although still working--is perhaps
physically damaged in some way and you wish to physically replace it with a new I-FOB
(contact your security professional and order part F-IFOB). If you press YES to this selec-
tion, the Touchpad will prompt you to insert a new I-FOB, thus replacing the existing Mas-
ter I-FOB. (In theory, you can insert the existing Master I-FOB, but this redundant opera-
tion will only overwrite the existing valid Master I-FOB code, thus "re-creating" a Master I-
FOB). Note: The Master I-FOB allows access to all system security features and thus
should be kept in a secure location.
Create User I-FOB
In addition to allowing the disarming of the system and silencing the siren, User I-FOB's
allow limited access to system features. You can add up to 5 additional "User" I-FOB's
USER PROGRAM MODE
CREATE MASTER I-FOB Y/N
CREATE USER I-FOB Y/N
F-64TPBR_OI319A.03_USER_...
page 20
Friday, September 15, 2006 10:39
Composite