Monessen Hearth CDVR33N/PV7;N/PE7;N/PSC7 Indoor Fireplace User Manual


 
CDVSC7 & CDV7 Series Gas Fireplace
69D3011
9


Read this homeowner manual thoroughly and follow all
instructions carefully. Inspect all contents for shipping
damage and immediately inform your dealer if any damage
is found. Do not install any unit with damaged, incomplete,
or substitute parts. Check your packing list to verify that
all listed parts have been received. You should have the
following:
Fireplace (Firebox and Burner System)
Log Set
Volcanic Rock
Rock Wool

 
Phillips Screwdriver Framing Materials
Hammer Wall Finishing Materials
Saw and/or saber saw Level
Electric Drill and Bits Tee Joint
Pliers Measuring Tape
Square Pipe Wrench
Caulking Material (Noncombustible)
Fireplace Surround Material (Noncombustible)
Piping Complying with Local Codes
Pipe Sealant Approved for use with Propane/LPG
(Resistant to Sulfur Compounds)

Firebox framing can be built before or after the appliance
is set in place. Construct firebox framing following Figure 2
for your specific installation requirements. Refer to Figure
2 for firebox dimensions. The framing headers may rest
on the top of the firebox standoffs.


The firebox may be installed directly on a combustible floor
or raised on a platform of an appropriate height. When
the firebox is installed directly on carpeting, tile, or other
combustible material, other than wood flooring, the firebox
shall be installed on a metal or wood panel extending the
full width and depth of the enclosure.

      
     


Firebox framing can be built before or after the appliance
is set in place. Construct firebox framing following Figure 3
for your specific installation requirements. Refer to Figure
3 for firebox dimensions. The framing headers may rest
on the top of the firebox standoffs.

The firebox may be installed directly on a combustible floor
or raised on a platform of an appropriate height. When
the firebox is installed directly on carpeting, tile, or other
combustible material, other than wood flooring, the firebox
shall be installed on a metal or wood panel extending the
full width and depth of the enclosure.






