Monessen Hearth CDVR33N/PV7;N/PE7;N/PSC7 Indoor Fireplace User Manual


 
CDVSC7 & CDV7 Series Gas Fireplace
0
69D3011

FP2294
Side View Vent Termination
1/25/00 djt
Finish Wall
Vent
Termination
FP94
Figure 17 -
Side View of Final Unit Location


Follow Steps 1 and  on Page 19.

Install the 4” (10 mm) flex vent pipe to the appliance col-
lars described in “General Information Assembling Vent
Pipes”, Page 1. If the installation requires a 45° angle,
grasp the vent pipe close to the appliance collar and bend
to 45°. DO NOT exceed 45°. Figure 18
Install the 7” vent pipe in the same manner as Step .
 There must be a 1/” (13 mm) rise in a 1” (305
mm) length of flex vent.

Assemble the flex vent to the collars on the termination as
you did on the appliance.
FP1473
corner flex install
4/04 djt
Termination
Flex Section
Appliance Collars
FP1473
Figure 18 -
Grasp the vent pipe close to the collar and
bend to 45° angle. do not exceed 45°.
FP1472
rise in length
4/04 djt
Rise
FP147
Figure 19 -
There must be a 1/2" rise per foot length

 For all top vent installations where a 90° elbow
is the first pipe piece towards a sidewall termination (up
and out), an open-center ringed flue restrictor must be
installed onto the top edge of the firebox flue adapter. To
create this open-center re-
strictor, twist and break off
the center rib of the supplied
flue restrictor. The installed
part should appear similar
to that show n in Figure 20.

  
 

  
   


The Vent Graph, showing the relationship between verti-
cal and horizontal side wall venting, will help to determine
the various dimensions allowable.



When vent termination exits through foundations less
than 0” (508 mm) below siding outcrop, the vent pipe
must flush up with the siding.
It is best to locate the fireplace in such a way that mini-
mizes the number of offsets and horizontal vent length.
The horizontal vent run refers to the total length of vent
pipe from the flue collar of the fireplace (or the top of the
Transition Elbow) to the face of the outer wall.
Horizontal plane means no vertical rise exists on this por-
tion of the vent assembly.

   

  
      

FP2303
CDV7 rear restrictor
3/09
Figure 20 -
Top Vent Vertical Sidewall
Restrictor
FP303