This appliance has been certified for use with either
natural or propane gas. See appropriate data plates.
This appliance is not for use with solid fuels.
The appliance is approved for bedroom or bedsitting
room installations.
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z3.1/NFPA 54 in the USA, CSA B149 in
Canada.
This appliance is mobile home approved.
The appliance must be properly connected to a venting
system.
The appliance is not approved for closet installations.
This appliance is approved to be vented with Simpson-
Duravent and MHSC Twist-Lock Direct Vent Compo-
nents.
FP2284a
CDV7 controls
Off/Pilot/On Knob
Remote Control
Switch Receiver
Figure 1 -
CDV7 Series Fireplace
Hi/Lo Knob
Blower
Control
On/Off/RS
Switch
Ignitor
FP84
The classification “noncombustible material” includes, but
is not limited to stone, brick and mortar. Noncombustibles
are safe to overlay the black-painted metal face (includ-
ing radiant plates) and do not pose a fire hazard. Do not
allow any noncombustible finish material to extend past or
interfere with fireplace opening.
The classification “combustible material” includes, but is not
limited to plywood, drywall and particle board. Combustible
materials may contact the sides, bottom or back of firebox.
Do not overlay the black painted face with combustible
materials.