OUTLINES AND DIMENSIONS
3
Detailed figure dwg (ABC)
(Knockout hole)
5/32(4) 1-31/32(50)
3/32(2.5) 5/8(16)
1-11/32(34)
13/32(10)
13/32(10) 1-25/32(45)
5°
3°
31/32(24.4)
45°
Knockout hole for
left piping
2-1/8(54)
3-19/32(91.5)1-25/32(45)
3/32(2.5)5/8(16)
1-31/32(50)
13/32(10)
Knockout holt for
under piping
Knockout hole for
remote control wiring
Knockout hole of
remote control wiring
Knockout hole of
right piping
R5/16(
R8)
R15/32(R12)
R5/16(R8)
R19/32(R15)
R19/32(R15)
R19/32(R15)
R5/16(R8)
3/16×1-3/8(4.5×35) 4 holes
8-:5/32(:4.3) holes
Installation plate
Piping hole:2-9/16(:65)
87-:3/16(:5.1)holes
4-:11/32(:9)holes
12-:1/8(:2.8)holes
3/16×1-15/32(4.5×37) 4 holes
3/16×1-9/16(4.5×40) 4 holes
Installation plate balance point hole
Knock of hole
2-3/8(60mm) or more for
left and left back piping.
Terminal block
Air intake
(Direction)
Address board
Note 1. Use M10 or W3/8 screw for installation plate.
Note 2. Extension piping side.
Note 3. In case of connecting MA-remote controller, please use
MA-remote controller cable in an accessories to the connector.
Transmission
Power supply
Address board
Detailed
Address setting digit
Mode selection
*3 Address board is protected
by a plastic cover.
Remove the screw holding
the cover with screw-driver
at the time of address setting.
Connection No.
Address board
(Direction)
installaion plate
Air intake
Air outlet
(Direction)
Required space
:5/8(:16) I.D
1/2F(:12.7)
1/4F(:6.35)
Drain pipe
Liquid pipe
Gas pipe
Refrigerart
piping
Liquid pipe
Gas pipe
Air outlet
Air intake
Air intake
13/32(10)
13/32(10)
16-1/32(407.5)
11-23/32(298)
10-1/4(260)
8-27/32(225)
7-15/32(190)
6-3/32(155)
4-23/32(120)
3-11/32(85)
1-3/16(30)
16-1/32(407.5)
12-29/32(328)
11-5/8(295)
10-1/4(260)
8-27/32(225)
7-15/32(190)
6-3/32(155)
4-23/32(120)
3-11/32(85)
1-3/16(30)
5-1/4(133)
2-27/32(72.5)
3-11/32(85)
1-7/8(47.5)
2-3/8(60)
7/8(22.5)
0
4-13/16(122.5)
4-1/32(102.5)
19/32(15)
12-29/32(328)
6-5/8(168)
4-7/16(113)
3-7/16(87)
5-5/16(135)
4-11/32(110)
1-3/8(35)
13/32(10)
4-7/8(124)
3-17/32(90)
6-1/4(159)
2-9/16(65)
1-9/16(40)
5-1/32(128)
11-23/32(298)
9-1/4(235)
8-1/16(205)
6-7/8(175)
6-11/16(170)
0
1-3/4(45)
4-29/32(125)
2-3/32(53)
1-3/32(27.5)
0
7-3/32(180)
6-1/4(159)
0
3-27/32(97.5)
8-1/16(205)
6-11/16(170)
9-1/4(235)
6-7/8(175)
1-23/32(44)
1-31/32(50)
Details of installation plate
Min55/64(22) Min25/32(20)
Min3-15/16(100)
Min3-35/64(90)
Min1-31/32(50)
1-7/16(37.8)
1/4
(7)
Air intake
25-3/16(640)
Air intake
32-1/8(815)
4-1/2(115)
4-3/16(106.7)
1/8(3)
11-5/8(295)
2-3/8
(60)
25-3/16(640)
27-3/8(695)
8-7/8(225) 3/16(5)
4-11/32(110)
4-9/16(116)
26-31/32(660)(Drain pipe total 29-29/32(760))
17-23/32(450)
20-25/32(520)
3-15/16(100.6)17/32(14)
30-13/16(783)
2-7/8
(74.6)
Air outlet
Air outlet
PKFY-P06NBMU-E
PKFY-P08NBMU-E
Unit : inch (mm)