Mitsubishi Electronics OCH461 Air Conditioner User Manual


 
18
J41, J42
Wireless
remote
controller
Pair No.
Jumper
<Initial setting>
Pattern A
Setting pattern
J41 J42
Indoor controller
jumper wire
Pair No. of wireless
remote controller
Initial setting
A
B
D
C
Cut
Cut
Cut
Cut
0
1
3
2
Pair No.4-9 of wireless remote controller is setting pattern D.
ON/OFF
TEMP
FAN
VANE
MODE
CHECK
LOUVER
TEST RUN
AUTO STOP
AUTO START
h
min
RESET
SET
CLOCK
MODEL SELECT
Model No.
Temperature
button
SET button
Pair No.
Minute
button
• To operate each indoor unit by each remote controller when installed 2 indoor
units or more are near, Pair No. setting is necessary.
Pair No. setting is available with the 4 patterns
(Setting
patterns
A to D).
.
Make setting for J41, J42 of indoor controller board and the Pair No. of
wireless remote controller.
•You may not set it when operating it by one remote controller.
Setting for indoor unit
Cut jumper wire J41, J42 on the indoor controller board according to the
table below.
Wireless remote controller pair number:
Setting operation
1. Press the SET button (using a pointed implement). Check that the
remote controller's display has stopped before continuing.
MODEL SELECT
flashes, and the model No. (3 digits) appears (steadily-lit).
2. Press the MINUTE button twice. The pair number appears flashing.
3. Press the temperature buttons to select the pair number to set.
4. Press the SET button (using a pointed implement).The set pair number is
displayed (steadily-lit) for 3 seconds, then disappears.
Operation by switch
Switch
Remarks
Under
operation
or
suspension
Effective
timing
0
5
9
4
8
3
7
2
6
1
SW12
10
0
5
9
4
8
3
7
2
6
1
SW11
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
SW14
0
5
9
4
8
3
7
2
6
1
SW12
0
5
9
4
8
3
7
2
6
1
SW11
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
SW14
Address board
Address board
<Initial setting>
<Initial setting>
SW11
1s digit
address
setting
SW12
10ths digit
address
setting
Rotary switch
SW14
Branch
No.
Setting
Rotary Switch
How to set addresses
Example : If address is "3", remain SW12
(for over 10) at "0", and match SW11 (for 1 to 9)
with "3".
How to set branch numbers SW14 (Series R2 only)
Match the indoor unit’s refrigerant pipe with
the BC controller’s end connection number.
Remain other than series R2 at "0".
Before
power
supply
ON