25
✦ To perform any of the advanced programming
steps, the Console must be in the Setup Mode.
✦ Each programming function is performed with
similar keystrokes. After the Console is in Setup
Mode, enter the programming step number,
press HOME, then enter the new value and press
AWAY. For reference, follow the fi gures next to the
programming steps.
✴ If the new value is accepted, a “bing” will sound. If the new
value is not accepted, a “double buzz” will sound.
CONSOLE PROGRAMMING OPTIONS
STEP # PROGRAMMING FUNCTIONS POSSIBLE VALUES FACTORY VALUE INSTALLATION VALUE
25 ENTRY DELAY 20-255 SECONDS 30
26 EXIT DELAY 20-255 SECONDS 60
30 BURGLARY SIREN TIME 1-30 MINUTES 5
31 EMERGENCY SIREN TIME 1-30 MINUTES 5
32 FIRE SIREN TIME 1-30 MINUTES 5
40 AUTOMATION OUTPUT TIME 0-2500 SECONDS (0 = TOGGLE ON/OFF) 0
50 REMOTE ARMING MODE 2 = HOME MODE; 3 = AWAY MODE 3
51 REMOTE DISARMING MODE 0 = OFF MODE; 1 = CHIME MODE 0
61 ENTRY DELAY BEEPS 0 = OFF; 1 = ON 1
62 EXIT DELAY BEEPS 0 = OFF; 1 = ON 1
63 SILENT BURGLARY ALARM 0 = AUDIBLE; 1 = SILENT 0
64 SILENT EMERGENCY ALARM 0 = AUDIBLE; 1 = SILENT 0
65 QUICK ARMING 0 = OFF; 1 = ON 1
66 AUTO RESTORE 0 = OFF; 1 = ON 1
67 AUTO BYPASS 0 = OFF; 1 = ON 0
68 AUTOMATION MODE DURING ALARM
0 = FLASH (ENABLED BY FUNCTION 72)
1 = STEADY (ENABLED BY FUNCTION 72)
0
69 AUTOMATION BING TOME
0 = NO BINGS
1 = BINGS
1
70 REMOTE ARM/DISARM CHIRP
0 = NO CHIRPS
1 = CHIRPS (1 CHIRP = ARMED, 2 CHIRPS = DISARMED)
1
71 AUTOMATION FLASHES AFTER ALARM
0 = STANDARD
1 = FLASHING AFTER ALARM
0
72 AUTOMATION ACTIVE DURING ALARM
0 = STANDARD
1 = AUTOMATION ACTIVE DURING ALARM
(FLASH OR STEADY PROGRAMMED BY FUNCTION 68)
0
73 AUTOMATION ON WHILE ARMED
0 = STANDARD
1 = ON WHILE ARMED
0
74 AUTOMATION ON DURING EXIT/ENTRY
0 = STANDARD
1 = ON DURING EXIT/ENTRY DELAY
0
75 AUTOMATION POLARITY 0 = + WHEN OFF; 1 = + WHEN ON 1
87 REMOTE ACCESS PASSWORD 6 DIGITS 987654
92 DURESS CODE 1-5 DIGITS REMOVED
93 RESTRICTED USER CODE #1 1-5 DIGITS REMOVED
94 RESTRICTED USER CODE #2 1-5 DIGITS REMOVED
95 RESTRICTED USER CODE #3 1-5 DIGITS REMOVED
96 RESTRICTED USER CODE #4 1-5 DIGITS REMOVED
97 RESTRICTED USER CODE #5 1-5 DIGITS REMOVED
98 PAGE ALERT USER CODE 1-5 DIGITS REMOVED
99 MASTER USER CODE 1-5 DIGITS 1234
SETUP MODE
1. Start with the Console in Test Mode (Setup Mode
cannot be reached from any other mode).
2. From Test Mode, enter the master user code then
press TEST.
✎ NOTE: Only the master user code can be used to
put the system into the Setup Mode. The restricted
user codes cannot access Setup Mode, only Code
Mode.
✴ A “Gong” and fi ve “Beeps” will sound, signaling that the
system is in Setup Mode.
3. After programming changes are complete, press
the OFF key for three seconds to exit Setup Mode.
✎ NOTE: If the system is left unattended in Setup
Mode, it will automatically switch back to Off Mode
after three minutes.
12. ADVANCED PROGRAMMING
HOME
TEST
= PROGRAM
= REMOVE
AWAY
= STORE
Console Programming Table