Linear DVS-2400 Home Security System User Manual


 
9
EXTERNAL CONSOLE SPEAKER CONNECTION
An external console speaker sounds system tones
and alerts occupants with a loud siren during alarm.
With the VB-2 module installed, the Central Station
can talk to the occupants through the external
console speaker.
Use an 8-ohm, 10 watt minimum rated speaker. Do
not use a horn/siren with a built-in siren driver.
Up to two 8-ohm speakers can be used with each
Console.
Up to 150 feet of 22 AWG wire can be used with
each speaker.
The system tone volume can be adjusted with the
annunciator volume control.
1. Mount the external speaker.
2. Route the speaker wires from the external speaker
to the Console.
3. Open the Console top cover and locate the main
terminal block.
4. Route the speaker wires up through the wiring
access hole.
5. Remove the wire jumper from the EXT. SPKR & (-)
terminals.
6. Connect the speaker wires to the EXT. SPKR & (-)
terminals.
NOTE: If connecting two external speakers,
connect the second speaker in parallel, to the
same EXT. SPKR & (-) terminals as the fi rst
speaker.
EXTERNAL ALARM SIREN CONNECTION
An external siren alerts occupants and neighbors
with a loud siren during alarm.
Use a 12 volt, 1 amp maximum rated weather-
resistant horn speaker with a built-in siren driver. Do
not use a plain speaker.
NOTE: Connection of an electromechanical bell or
motor bell is not recommended because of the radio
interference generated when the bell is running.
UL NOTE: Not for use in UL installations.
1. Mount the external siren.
2. Route the wires from the external siren to the
Console.
3. Open the Console top cover and locate the main
terminal strip.
4. Route the siren wires up through the wiring access
hole.
5. Connect the siren wires to the RELAY N.O. & (-)
terminals.
NOTE: By removing the Console’s auxiliary fuse,
the relay contacts will become isolated. Use the
RELAY N.O. & RELAY DRY terminals to switch an
externally powered load.
AC
AC
EXT. SPKR
(-)
H/A -
H/A +
RELAY N.O.
RELAY DRY
MAIN TERMINAL BLOCK
EXT. SPKR(S)
8 OHM/10 WATT
2 SPKRS MAX.
NOTE: REMOVE
JUMPER FOR
EXT. SPEAKERS
OPTIONAL
VOICE MODULE
MODEL: VB-2
MAIN
TERMINAL
BLOCK
ANNUNCIATOR
VOLUME
CONTROL
LINEAR SECURITY CONSOLE MODEL DVS-2400
CONNECT SPEAKER LEADS
TO EXT. SPKR & (-) TERMINALS
REMOVE
JUMPER
EXTERNAL
CONSOLE
SPEAKER
8 OHM, 10 WATT
MINIMUM
AC
AC
EXT. SPKR
(-)
H/A -
H/A +
RELAY N.O.
RELAY DRY
MAIN TERMINAL BLOCK
EXTERNAL SIREN
12 VDC 1 AMP
MAXIMUM
OPTIONAL
VOICE MODULE
MODEL: VB-2
MAIN
TERMINAL
BLOCK
LINEAR SECURITY CONSOLE MODEL DVS-2400
EXTERNAL
CONSOLE
SPEAKER
EXTERNAL
ALARM
SIREN
CONNECT SIREN LEADS TO
(-) & RELAY N.O. TERMINALS
EXTERNAL
ALARM RELAY
12 VDC 1 AMP
MAXIMUM