1110 West Taft Avenue • Orange, CA 92865
Figure 67
Step 9. Reassemble all removed components
by reversing the procedures outlined in the
preceding steps. Use pipe joint compound or
Teflon tape on all pipe fittings before installing
(ensure propane resistant compounds are used
in propane applications, do not use pipe joint
compounds on flare fittings).
Step 10.Attach the conversion label provided
in the conversion kit to the rating plate on the
appliance.
Step 11. Turn on gas supply and test for gas
leaks.
Figure 66
When reinstalling the ignitor assembly, use
extreme care to prevent damage and break-
age. Do not apply any leverage to the ignitor
assembly while restoring the retainer clip to
its original position.
All Models
Step 8. Remove the burner orifice from the
manifold and replace it with the one pro-
vided with the kit. See the following table for
orifice sizes for natural and propane mod-
els
. Figure 67
illustrated the orifice.
Figure 65
Step 6. Electronic Appliances -
Honeywell Systems
See
Figure 65
and the instructions provided
with the kit. Remove the slotted cap screw,
o-ring, pressure-regulating adjusting screw
and spring. Retain all parts for possible later
use. Install new components from the kit.
Black cap and red spring for propane gas
units. Silver cap and stainless steel spring
for natural gas units. Before installing the
cap, attach manometer to the manifold side
pressure test fitting and adjust screw until
pressure reads 3.5 inches water column (0.87
kPa) for natural gas, and 10.0 inches water
column (2.49 kPa) for propane gas.
See
Figure 66
and replace the pilot orifice as
follows: Remove the ignitor assembly retainer
clip, and carefully remove the ignitor assembly.
Exercise extreme care to prevent damage to
or breakage of the ignitor assembly. Remove
the screw securing the pilot assembly to its
mounting bracket. Back off the flare nut at the
end of the pilot gas line to free the pilot
assembly from the gas line. Remove the pilot
orifice and replace it with the one provided
with the conversion kit. Reinstall the pilot
assembly by reversing the steps detailed here.
ledoM
seireS
ezisecifirO
noitavelE
teeF
)sretem(
.taN.porP
8233-TDPM
8233-RDPM
54#hcni840.0
0054-0
)0731-0(
0353-DPM44#55#
5304-DPM73#hcni260.0
0454-DPM63#25#
Spring
Adjusting
Screw
Slotted
Cap
P
S
I
OFF
I
ON
CONTROL
I
G
N
I
T
E
Manifold
Pressure
Test Port
Inlet Pressure Test Port
Note:
If the ignitor is damaged, a replacement kit is available - order Catalog Number 87L54.
Retaining
Clip
Ignitor
Assembly
Pilot
Assembly
Pilot
Orifice
Flare Nut