NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
LENNOXHEARTHPRODUCTS•MERIT
®
SERIESDIRECT-VENTCONTEMPORARYDESIGNGASFIREPLACES•MODELMLDVTCD-35•INSTALLATIONINSTRUCTIONS
FIREPLACE FRAMING SPECIFICATIONS
Never use galvanized or plastic pipe. Refer
to Table 6 for proper sizing of the gas sup-
ply line, if black iron pipe is being used. Gas
lines must be routed, constructed and made
of materials that are in strict accordance with
local codes and regulations. We recommend
that a qualified individual such as a plumber or
gas fitter be hired to correctly size and route
the gas supply line to the appliance. Installing
a gas supply line from the fuel supply to the
appliance involves numerous considerations of
materials, protection, sizing, locations, controls,
pressure, sediment, and more. Certainly no one
unfamiliar and unqualified should attempt sizing
or installing gas piping.
Schedule 40
Black Iron Pipe
Inside Diameter (Inches)
Schedule 40 Pipe
Length (feet)
Natural
Gas
Propane
Gas
0-10 1/2 3/8
10-40 1/2 1/2
40-100 1/2 1/2
100-150 3/4 1/2
150-200 3/4 1/2
Table 6
Notes:
• All appliances are factory-equipped with a
exiblegaslineconnectorand1/2inchshutoff
valve (see Figure 38 on Page 26).
• SeeMassachusetts Requirements on Page 4
for additional requirements for installations in
the state of Massachusetts in the USA.
• ThegassupplylineshouldNotbeconnected
to the appliance until Step 6 (Page 26).
• Apipejointcompoundratedforgasshouldbe
used on the threaded joints. Ensure propane
resistant compounds are used in propane
applications. Be very careful that the pipe
compound does not get inside the pipe.
• Itisrecommendedtoinstallasedimenttrap
in the supply line as close as possible to the
appliance. Appliances using Propane should
have a sediment trap at the base of the tank.
• Checkwithlocalbuildingofcialforlocalcode
requirements (i.e. are below grade penetrations
of the gas line allowed?, etc).
IMPORTANT: If propane is used, be aware that
if tank size is too small (i.e. under 100-lbs, if
this is the only gas appliance in the dwelling.
Ref. NPFA 58), there may be loss of pressure,
resulting in insufficient fuel delivery (which
can result in sooting, severe delayed ignition
or other malfunctions). Any damage resulting
from an improper installation, such as this, is
not covered under the limited warranty.
Figure 12 - Corner Framing with Horizontal Termination
Inches
(millimeters)
C
Back wall of chase/enclosure
(including any finishing materials)
D
E
A
B
7 (178)
.oNledoM A B D E
35 1/4
57 1/2
40 5/8
28 3/4
in.
895
1461
1032
730
mm
C
13 3/4
349
MLDVTCD-35
Also see Figure 11 on Page 10.
Figure 13 - ROUTE GAS LINE
*3"
(76 mm)
Left Side Front
Corner of Fireplace
Framing
6-1/2"
(152 mm)
Pipe Coupling
(Recommended)
*From Floor Or Raised Platform
Step 2. ROUTING GAS LINE
Route a 1/2" (13mm) gas line to the left side
of the appliance as shown in Figure 13. Gas
lines must be routed, constructed and made
of materials that are in strict accordance with
local codes and regulations. All appliances
arefactory-equippedwithaexiblegasline
connector and 1/2 inch shutoff valve (see Step
6 on Page 26).
Proper Sizing of Gas Line
Properly size and route the gas supply line
from the supply regulator to the area where the
appliance is to be installed per requirements
outlined in the National Fuel Gas Code, NFPA
54 - latest edition (USA) or CAN/CSA-B149.1
- latest edition (Canada).