Kidde 0910UK Smoke Alarm User Manual


 
9. KIDDE RECOMMENDATIONS
Smoke alarms shall be installed outside each separate sleeping area in the immediate
vicinity of the bedrooms and on each additional story of the family living unit, includ-
ing basements and excluding crawl spaces and unfinished attics. In new construction,
a smoke alarm also shall be installed in each sleeping room.
Smoke Detection - Are More Smoke Alarms Desirable? The required number of
smoke alarms might not provide reliable early warning protection for those areas sep-
arated by a door from the areas protected by the required smoke alarms. For this rea-
son, it is recommended that the householder consider the use of additional smoke
alarms for those areas for increased protection. The additional areas include the base-
ment, bedrooms, dining room, utility room, and hallways not protected by the
required smoke alarms. The installation of the smoke alarms in the kitchen, attic (fin-
ished or unfinished), or garage is normally not recommended, as these locations occa-
sionally experience conditions that can result in improper operation.
10. SERVICE AND WARRANTY
If after reviewing this manual you feel that your smoke alarm is defective in any way,
do not tamper with the unit. Return it for servicing to: Kidde Safety Europe,,
Mathisen Way, Colnbrook, Slough, Berkshire SL3 OHB. (See Warranty for in-warranty
returns).