Kenmore 625.34847 Water System User Manual


 
SE!_T_ON 5 SERVICE TECH. iNFORMATiON
f !
5A. TROUBLESHOOTING
,,,, ,,,,,,,.,,, ,,, ,,..........................................
CORRECT
SWITCH
DISPLAYS
-p
VALVE CYCLE STATUS
Valve in service, fill, brining, back-
wash or fast rinse position
i Valve rotating from one position to
i another
C. While in this diagnostic screen, the following in-
formation is available and may be beneficial for
various masons, This information is retained by
the computer fiom the first time electrical power
is applied to the face plate.
-- Press [] to display the number' of days this
face plate has had electrical power applied,
-- Press [] to display the number' of regenera-
tions initiated by this face plate since the SRcode
number was entered.
2_ Press the SELECTbutton and hold 3 seconds un-
til,o.
CODE i
SR 22 shows. ...,', ==,,,..
This code identifies the softener nominal capacity
size. If the wrong number shows, the softener will
operate on incorrect programming. Do the following
as needed,
Return the present time display: Press the
SELECT button.
Change the SR number: To displa# the correct SR
number', press the[]UP or DOWN {_]button. Press
SELECT, and reset the tirner_
NOTE:
If the face plate is left in a diagnostic display (Or a flashing
display when setting times or hardness), present time
automatically returns if a button is not pressed within 4
minutes.
FACE PI.ATE REPLACEMENT: Be sure the valve is in
service position (observe valve cycle indicator)
when replacing the face plate.
If, after' installing and programming the replacement face
plate, the valve is not in service position, do the follow.
ing to assure correct cycle orientation, or' timing, be-
tween the face plate and valve
Use the MANUAL ADVANCE procedures, page 22. With
the RECHARGE NOW button, advance through the re-
charge cycles until the valve stops in service position,
and RECHARGE no longer flashes in the timez:
NOTE: The valve motor may automatically drive through
several valve positions while searching for service If an
error code occurs, unplug the transformer, then plug in
again
1/'10 NI