ITT ICS Water Pump User Manual


 
8
3 HP Only
Pump Suction NPT Discharge NPT L R W X *Wt. Max.
1 x 1¼-5 1 7.35 .94 3.01 4.62 17
x 1½-5 7.22 1.06 2.88 4.56 17
Motor Weights
HP Single Phase Three Phase C Max. Length
ODP TEFC ODP TEFC X-Proof
3 40 45 42 37 13.34
Dimensions in inches, weight in pounds.
Dimensions and Weights – Determined by Pump
58317 CF–8M
1.59
SINGLE PHASE ONLY
5.31
MAX.
7.10
MAX.
5.88
1.5 1.5L
1
4
NPT (OPTIONAL)
2.88
3.38
SUCTION
DISCHARGE
W
C
MAX.
SLOT .34 WIDE
X .88 TO
C
L
C
L
5.28 3HP 1 PHASE ONLY
3.50
X
3.50
.19
2.442.44
6.50
4.88
MAX.
R
Available Motor Dimensions and Weights
½ HP – 2 HP
2.50
58317 CF–8M
1.59
SINGLE PHASE ONLY
6.31
MAX.
6.50
2.50L
1
4
NPT (OPTIONAL)
2.88
3.38
SUCTION
DISCHARGE
W
C
MAX.
.41 DIA HOLES
4 PLACES,
3.50
X
4.12
2.942.94
6.75
4.88
MAX.
R
2.66
Pump Suction NPT Discharge NPT L R W X *Wt. Max.
1 x 1¼-5 1 3.75 .94 3.01 4.62 17
x 1½-5 3.62 1.06 2.88 4.56 17
Dimensions and Weights – Determined by Pump
Motor Weights
HP Single Phase Three Phase
ODP TEFC EXP ODP TEFC EXP
½
16 21 47 19 18 27 9
15
16
¾ 19 24 41 21 21 30 10¼
1 22 26 49 23 21 30 11
28 35 56 27 27 37 11
5
16
2 33 39 60 32 33 44 12
1
16
Available Motor Weights and Dimensions
NOTES:
1. Pumps will be shipped with top vertical discharge as standard, for other
orientations, remove casing bolts,rotate to desired position, and tighten
3
8
" bolts
to 24 lbs.-ft.
2. Dimensions in inches, weight in pounds.
3. Not to be used for construction purposes unless certifi ed.
4. Motor dimensions may vary with motor manufacturers.
* Weight is liquid end only. For complete pump, add weight of applicable
motor.
C Max.
Length
ICS – Engineering Data