Honeywell Ademco Vista Series Commercial Burglary Partitioned Security System With Scheduling Home Security System User Manual


 
8
1*40 1*41 NON-ALARM DIALER CODES
Enter 00-09; B-F (11-15).
Default = 00 for all reports
1*40 1st Digit 1*41 2nd Digit
Armed STAY
|
|
Time/Date Set or Event Log Reset
|
|
Event Log 50% & 90% Full
|
|
Event Log Overflow
|
|
Exit Error (Zone)
|
|
Exit Error (User)
|
|
Recent Close
|
|
1*42 CALL WAITING DEFEAT [0]
1=Yes; 0=No
1*43 PERM. KEYPAD BACKLIGHT [0]
1=enable; 0=disable When disabled, display lights when any
key is pressed, and turns off after period of keypad inactivity.
1*44 WIRELESS KEYPAD TAMPER [0]
DETECTION
1=enable; 0=disable.
Must be "0" for UL installations.
1*45 EXIT DELAY SOUNDING [0]
1=enable; 0=disable. Produces quick beeping during exit
delay if enabled.
1*46 AUXILIARY OUTPUT MODE [0]
Enter 0 for ground start output.
Enter 1 for open/close trigger (is produced only if all partitions
are armed.
Enter 2 for keypad-like sounding. Applies to the partition
enabled in field *15.
Enter 3 if AAV module is being used.
NOTE: Only one of the above options may be active within
the system.
1*47 CHIME ON EXTERNAL SIREN [0]
1=enable; 0=disable
1*48 WIRELESS KEYPAD ASSIGNMENT [0]
0=disable; enter partition in which RF keypad used, 1-8.
Must be "0" for UL installations.
1*49 SUPPRESS TX SUPERVISION SOUND [1]
1=disable; 0=enable.
Must be "0" for UL installations.
1*52 SEND CANCEL IF ALARM + OFF [1]
1=no restriction; 0=within bell timeout period only
1*53 DOWNLOAD CALLBACK [0]
1=callback not required; 0=callback required.
Must be "0" for UL installations.
1*57 5800 RF BUTTON GLOBAL ARM [0]
1=enable; 0=disable
1*58 5800 RF BUTTON FORCE ARM [0]
Enter "1" to enable. If a zone is faulted after pressing button,
keypad will beep once. Pressing the button again within 4
sec. bypasses the zone. Enter "0" to disable.
Must be "0" for UL installations.
1*60 ZONE 5 AUDIO ALARM VERIFICATION [0]
Enter 1 If 2-way audio (AAV) is being used; Enter 0 if it is
not.
Must be "0" for UL installations.
1*69 PRINTER TYPE [0]
Enter 0 if you are using a parallel printer connected to the
VA8201 Alpha Pager Module.
Enter 1 if you are using a serial printer.
1*70 EVENT LOG TYPES
[1 0 0 0 1]
Alarm
Chk
Byp
O/C
Syst
1=enable; 0=disable
1*71 12/24 HOUR TIME STAMP FORMAT [0]
0=12 hour; 1=24 hour
1*72 EVENT LOG PRINTER ON-LINE [0]
0=disable; 1=enable
1*73 PRINTER BAUD RATE [0]
1=300; 0=1200
1*74 RELAY TIMEOUT XXX MINUTES [000] | |
Enter the relay timeout, 000-127 in multiples of 2 minutes,
desired for #80 Menu Mode time-driven event relay
command numbers "04/09" and #93 Menu Mode Output
Programming output command "56."
1*75 RELAY TIMEOUT YYY SECONDS [000] | |
Enter the relay timeout, 000-127 seconds, desired for #80
Menu Mode time driven event relay command numbers
"05/10" and #93 Menu Mode Output Programming command
"57."
1*76 ACCESS CONTROL RELAY [00] |
Relay will be pulsed for 2 seconds whenever code + [0] is
pressed. Enter 00-16; 00=none.
Must be "00" for UL.
3rd Page Programming Fields (press *94)
2*00
NUMBER OF PARTITIONS [1]
Enter 1-8
2*01 DAYLIGHT SAVING TIME [04, 10] | |
START/END MONTH Start End
00-12; if no daylight saving time, enter 00,00
2*02 DAYLIGHT SAVING TIME [1, 5] |
START/END WEEKEND Start | End
Enter 1-7. 1=first; 2=second; 3=third; 4=fourth; 5=last;
6=next to last; 7=3rd from last [1,5]
2*05 AUTO-ARM DELAY [15] |
Enter the time between the end of the arming window and
the start of auto-arming warning period, in values of 1-14
times 4 minutes 00=instant; [15=no auto arm at all]. When
this delay expires, the Auto-Arm Warning Period begins.