Honeywell Ademco Vista Series Commercial Burglary Partitioned Security System With Scheduling Home Security System User Manual


 
40
ZT = ZONE TYPE/SYSTEM OPERATION
Choices for Start/Stop Zone Types and System Operations:
00 = No Response (Not Used) 23 = No Alarm Response 43 = Communication failure
01 = Entry/Exit #1 31 = End of Exit Time 44 = RF Low Battery
02 = Entry/exit #2 32 = Start of Entry Time 45 = Polling Loop Failure
03 = Perimeter 33 = Any Burglary Alarm 51 = RF Receiver Failure
04 = Interior Follower 34 = Code + [#] + 71 Key Entry 52 = Kissoff
05 = Trouble Day/Alarm Night 35 = Code + [#] + 72 Key Entry 54 = Fire Zone Reset
06 = 24-Hr. Silent 36 = At Bell Timeout ** 55 = Disarm + 1 Minute
07 = 24-Hr. Audible 37 = 2 Times Bell Timeout ** 56 = XX Minutes (enter XX in field 1*74) *
08 = 24-Hr. Auxiliary 38 = Chime 57 = YY Seconds (enter YY in field 1*75) *
09 = Fire Alarm or Trouble 39 = Fire Alarm 58 = Duress
10 = Interior W/Delay 40 = Bypassing
20 = Arming-STAY*** 41 = AC Power Fail
21 = Arming-AWAY**** 42 = System Battery Low
60 = Audio Alarm Verification (must be
selected for both START and STOP
operation)
22 = Disarming (Code + Off)
NOTE: Any zone in "ZT" for Start, going into alarm, fault, or trouble will activate the relay.
Any zone in "ZT" for Stop, that restores will stop the relay action.
* Stop condition only
** Or at Disarming, whichever occurs earlier
*** The output also activates when the partition is armed in the INSTANT mode
**** The output also activates when the partition is armed in the MAXIMUM mode
P = PARTITION No. 1-8, 0 = Any
ZONE LISTS FOR OUTPUT DEVICES Programmed in the #93 Menu Mode in the Output Programming Section. Fill in the
required data on the worksheet below and follow the procedure shown earlier in this Programming Guide as you enter the
data during the displays and prompts that appear in sequence. Up to 8 zone lists may be created
Note: Record desired zone numbers below. More or fewer boxes than shown may be needed, as any list may include any or
all of system's zone numbers.
Zone List 1: Started or stopped by zone numbers (enter 00 to end entries).
Zone List 2: Started or stopped by zone numbers (enter 000 to end entries).
Zone List 3: Started or stopped by zone numbers (enter 000 to end entries).
Zone List 4: Started or stopped by zone numbers (enter 000 to end entries).
Zone List 5: Started or stopped by zone numbers (enter 00 to end entries).
Zone List 6: Started or stopped by zone numbers (enter 000 to end entries).