Honeywell Ademco Vista Series Commercial Burglary Partitioned Security System With Scheduling Home Security System User Manual


 
44
Below is a list of the "Action" codes (desired actions) used when programming time-driven events. Note that these codes are
independent of the "relay codes" programmed during the #93 Menu ModeRelay Programming mode. If using Time Driven
Events, the following menu items must first be programmed using #93 Menu Mode - Relay Programming:
Enter Relay No. (reference identification number)
Relay Group (if applicable)
Restriction
Relay Type (4204 or X-10)
ECP Address (4204)
Relay No. (4204)
House Code (X-10)
Unit Code (X-10)
Relay commands:
Action Specifier for commands 01-05 is Relay No.; Action Specifier for commands 06-10 is Relay Group No.
01 = Relay On 02 = Relay Off
03 = Relay Close for 2 seconds 04 = Relay Close XX minutes (field 1*74)
05 = Relay Close YY seconds (field 1*75) 06 = Relay Group On
07 = Relay Group Off 08 = Relay Group Close for 2 seconds
09 = Relay Group Close XX minutes (field 1*74) 10 = Relay Group Close YY seconds (field 1*75)
Arm/Disarm commands:
Action Specifier for commands 20-24 is Partition(s). Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid
choices for auto-arming and disarming functions.
20 = Arm-Stay 21 = Arm Away
22 = Disarm 23 = Force Arm Stay (Auto-bypass faulted zns)
24 = Force Arm Away (Auto-bypass faulted zns)
Bypass commands:
Action Specifier for commands 30-31 is Zone List #, Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid
choices for bypass commands.
30 = Auto bypass - Zone list 31 = Auto unbypass - Zone list
Open/Close Windows:
Action Specifier for commands 40-41 is Partition(s), and for 42 is Access Group. Activation time 3 (During) are the only valid
choices for these commands.
40 = Enable Opening Window 41 = Enable Closing Window 42 = Enable Access Window
Activation time:
Refers to when the action is to take place relative to the time window.
1 = Beginning of time window
2 = End of time window
3 = During time window active period only (On at beginning of window, off at end).
4 = Beginning and end of time window
Limitation of Access Worksheet The system provides up to 8 Access Schedules that can be programmed for the system.
Fill in the required data on the worksheet below and follow the procedure in the installation instructions as you enter the data
during the displays and prompts that appear in sequence.
Acc Mon Tues Wed Thurs Fri Sat Sun Hol
Sch W1 W2 W1 W2 W1 W2 W1 W2 W1 W2 W1 W2 W1 W2 W1 W2
1
2
3
4
5
6
7
8