Heatiator BCDV36 Indoor Fireplace User Manual


 
01-03 9 33606 Rev D
BUILDER'S CHOICE SERIES INSTALLATION INSTRUCTIONS
c. No Elbows
The maximum horizontal run with no vertical
sections of vent is 18 from the back of the
appliance to the base of the cap. See Figure 7.
d. A 45° Elbow
For corner venting, a maximum of one 45° elbow
may be used. The maximum horizontal run
following the elbow is 12 to the base of the cap.
See Figure 8.
Figure 7
Rear Vented Appliances
Figure 8
One 45° Elbow
Figure 9
Two Elbows
e. Two Elbows
Figure 9 shows various venting configura-
tions using two elbows to terminate horizon-
tally. The maximum vertical run is 20 and the
maximum horizontal run is 14.
f. Three Elbows - One Elbow Horizontal
Figure 10 shows various venting
configurations using three elbows to
terminate horizontally. The maximum vertical
run is 20 and the maximum horizontal run is
12.
Figure 10
Three Elbows