Heatiator BCDV36 Indoor Fireplace User Manual


 
01-03 21 33606 Rev D
BUILDER'S CHOICE SERIES INSTALLATION INSTRUCTIONS
M. FUEL CONVERSION
Do not burn wood or other material in this appliance.
Natural or propane gas conversions necessary to meet the application need to be made by a qualified technician using
Hearth & Home Technologies specified and approved parts.
In the event your appliance must be converted to use propane, you must use a CKP Conversion Kit. To be converted to
use natural gas, you must use a CKN Conversion Kit. See Figure 26.
N. START-UP ISSUES
eussIsnoituloSelbissoPdnasesuaC
.1:ssalgehtnonoitasnednoC erutarepmetdnanoitsubmocsagfotluserasisihT
dluohsnoitasnednocsiht,smrawecnailppaehtsA.snoitairav
.raeppasid
.2:semalfeulB nigeblliwsemalfehtdnanoitarepolamronfotluserasisihT
.nrubotdewollasiecnailppaehtsawolleyot
.3:ecnailppaehtmorfrodO rofrodonaesaeleryamecnailppasiht,detarepotsrifnehW
ehtfognirucehtybdesuacsisihT.sruohlarevestsrifeht
morfgniniamerslioynaynaffogninrubehtdnatniap
.gnirutcafunam
.4:ssalgehtnomliF dnatniapehtfossecorpgnirucehtfotluserlamronasisihT
laitinifosruoh6-4nihtiwdenaelctonsissalgehtfI.sgol
,evomerotrenaelcevisarbanonaeriuqeryamsiht,gninrub
.ossarBsahcus
WARNING!
Never use gaso-
line, gasoline-type
lantern fuel, kero-
sene, charcoal
lighter fluid or
similar liquids in
this appliance.
Keep any flam-
mable liquids a
safe distance
from the appli-
ance.
O. MAINTENANCE INSTRUCTIONS
1. CLEANING THE BURNER AND CONTROL COMPARTMENT
Keep the control compartment clean by brushing and vacuuming at least once a year. Failure to do so may shorten the
life of the components. Always turn off the wall switch (or remote control) and gas valve before cleaning. Failure to do
so may shorten the life of the components.
2. CHECKING FLAME PATTERNS
Check the flame of the burner periodically, making sure the flames are steady, not lifting or floating. The flame color should
be blue with yellow tips. The thermopile and thermocouple tips should be covered with flame. See Figure 32.
If the vent configuration is installed incorrectly, the venting may cause the flames inside the appliance to lift or ghost,
which is a dangerous situation. Inspect the flames after installation to ensure proper performance. See Figure 33. If
the vent configuration is correct, yet the flames are lifting or ghosting, shut off the gas to the appliance and contact the
dealer.
3. VENTING SYSTEM INSPECTION
The appliance and venting system should be inspected before use and at least annually by a qualified field service
person to ensure that the flow of combustion and ventilation air is not obstructed.
Figure 33 - Flame Patterns
Figure 32 - Standing Pilot
Flame covers top 1/2 of thermopile and thermocouple.