Heat & Glo LifeStyle SUPREME-P-I30AU Electric Heater User Manual


 
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/128
A. ApplianceCertication
1
ListingandCodeApprovals
MODELS: Supreme-N-I30-AU,Supreme-P-I30-AU
LABORATORY: SAIGlobal
TYPE: GasSpaceHeatingAppliance
STANDARD: AS4553-2008
C. HighAltitudeInstallations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 ft. (610 m) elevation:
Reduce input rate 4% for each 1000 ft. (305 m) above
2000 ft. (610 m).
D. Non-CombustibleMaterialsSpecication
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
StandardTestMethodforBehaviorofMaterialsina
VerticalTubeFurnaceat750ºC(1382ºF)and UL763
shall be considered non-combustible materials.
E. CombustibleMaterialsSpecication
Materials made of or surfaced with wood, compressed pa-
per, plant bers, plastics, or other material that can ignite
and burn, whether ame proofed or not, or plastered or
unplastered shall be considered combustible materials.
F. ElectricalCodes
All electrical safety testing has been done following the EN
60335-2-102 standard. Local codes apply.
The Heat & Glo gas appliances discussed in this Installer’s
Guide have been tested to certication standards and listed
by the applicable laboratories.
This appliance must be installed in accordance with the
rules in force.
NOX Class 5 for G20, NOX Class 5 for G31
B. GasPressureRequirements
WARNING! Risk of Explosion! An in-line regulator
MUST be installed if the gas pressure exceeds 3.4 kPa.
Failure to install a regulator could damage valve.
Pressure requirements for Supreme-N-I30AU and Su-
preme-P-I30AU replaces are shown in table below.
Two taps are provided on the right hand side of the gas
control for a test gauge connection to measure the inlet
and outlet pressures.
The replace and its individual shut-off valve must be dis-
connected from the gas supply piping system during any
pressure testing of the system at test pressures in excess
of 60 mbar or 6 kPa.
If the replace must be isolated from the gas supply pip-
ing system by closing an individual shut-off valve, it must
be of the handle-less type.
Natural Gas Propane
Inlet Gas Pressure 1.13 - 3.40 kPa 2.75 - 3.40 kPa
Outlet (Manifold) Gas Pressure .80 - .95 kPa 2.36 - 2.61 kPa
Maximum Gas Consumption 31.9 MJ/h 30.9 MJ/h
Burner Injector DMS 36 (2.70 mm) DMS 52 (1.61 mm)
Pilot Injector .023 .014
An in-line regulator MUST be installed if the gas pressure exceeds 3.40kPa. Failure to install a regulator could damage
valve.