Heat & Glo LifeStyle SUPREME-P-I30AU Electric Heater User Manual


 
Heat & Glo • Supreme-N-I30AU, Supreme-P-I30AU • 2222-900 Rev. P • 6/1246
11
Finishing
A. MantelandWallProjections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specied. Framing or nishing
material closer than the minimums listed must be construct-
ed entirely of noncombustible materials (i.e., steel studs,
concrete board, etc).
Clearance to combustible material under the insert is 1/4
in. (6 mm). Clearance from top of replace opening for
combustibles extending 12 in. (305 mm) max. is 12 in.
(305 mm).
• Use leveling legs to raise insert minimum 1/4 in. (6 mm)
above combustible material or outer wrap of factory built
rebox.
Combustible facings must not extend behind the insert
surround. For non-combustible material specications
refer to section 1.E.
Figure11.1 ClearancestoMantelsorotherCombustibles
aboveAppliance
12 in.
(305 mm)
MIN.
12 in.
(305 mm)
MAX.
NON-COMBUSTIBLE FACING
MINIMUM CLEARANCE
TO COMBUSTIBLE
MANTEL OR
PROJECTION