Heat & Glo LifeStyle LUX60 Indoor Fireplace User Manual


 
Heat & Glo • LUX60 • 4062-116 • Rev. G • 4/11 53
A. IntelliFire (IPI) Ignition System (continued)
Symptom Possible Cause Corrective Action
4. Pilot lights but continues
to spark, and main burner
will not ignite. (If the pilot
continues to spark after
the pilot ame has been lit,
ame recti cation has not
occurred.)
A. A shorted or loose connection
in ame sensing rod.
Verify all connections to wiring diagram in manual. Verify
connections underneath pilot assembly are tight. Verify
connections are not grounding out to metal chassis, pilot burner,
pilot enclosure or screen if present, or any other metal object.
B. Poor ame recti cation or
contaminated ame sensing
rod.
With xed glass assembly in place, verify that ame is engul ng
ame sensing rod on left side of pilot hood. Flame sensing rod
should glow shortly after ignition. Verify correct pilot ori ce is
installed and gas inlet is set to pressure speci cations.
C. Module is not grounded. Verify module is securely grounded to metal chassis of appliance.
Verify that wire harness is rmly connected to the module.
D. Damaged pilot assembly or
contaminated ame sensing
rod.
Verify that ceramic insulator around the ame sensing rod is not
cracked, damaged, or loose. Verify connection from ame sensing
rod to white sensor wire. Clean ame sensing rod with emery
cloth to remove any contaminants that may have accumulated on
ame sensing rod. Verify continuity with a multimeter with ohms
set at lowest range. Replace pilot if any damage is detected.
E. Module. Deactivate the replace with the POWER button of the remote.
Remove ignitor wire “I” from module. Reactivate the replace
with the POWER button of the remote. If there is no spark at
“I” terminal module must be replaced. If there is a spark at “I”
terminal, module is ne.