Hearth and Home Technologies QV36B-A Indoor Fireplace User Manual


 
Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. U • 1/12 53
B. Facing Material
Metal front faces may be covered with non-combustible
materials only.
• Facing and/or nishing materials must not interfere with
air ow through louvers, operation of louvers or doors,
or access for service.
• Facing and/or nishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
• Seal joints between the nished wall and appliance top
and sides using a 300ºF minimum sealant. Refer to
Figure 13.5.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as speci ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
Figure 13.5 Noncombustible Facing Diagram
0 IN.
0 IN.
0 IN.
NON-COMBUSTIBLE
BOARD (INCLUDED)
1 IN.
FACING MATERIAL UP TO 1/2 IN. THICK
MAY BE COMBUSTIBLE - TOP AND SIDES
1 IN.
1 IN.
BOTTOM 1 INCH MAY BE COVERED WITH
COMBUSTIBLE OR NON-COMBUSTIBLE
MATERIAL.
HIGH TEMPERATURE (300º F / 149º C MIN.)
TOP & SIDE SEAL JOINT