Hearth and Home Technologies QV36B-A Indoor Fireplace User Manual


 
Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. U • 1/12 27
Top Vent - Vertical Termination
No Elbow
V
1
= 60 ft. Max. (18.3 m)
Figure 7.8
INNER HEAT SHIELD
Top Vent Application
Rear Vent Application
Note: Be sure to re-
install the inner heat
shield after exhaust
restrictor installation.
Figure 7.7
Exhaust restrictors are recommended for these verti-
cally terminated products which have excessive draft.
Exhaust restrictors will compensate for high draft, and
restore visual ame height. If the vent con guration has
a total vertical of 15-60 feet, an exhaust restrictor may
be needed. The exhaust restrictor can be located in the
appliance manual bag.
Exhaust restrictor Instructions
1. Install the exhaust restrictor over the center of the ex-
haust outlet in the rebox (see Figure 7.8).
2. Center the exhaust restrictor in the open end of the
exhaust outlet and secure through the slots on the ex-
haust restrictor with the 2-1/4 in. self tapping screws
provided in the appliance manual bag.
Exhaust restrictor
Exhaust restrictor
To access the
exhaust openings,
remove the inner
heat shield. To
remove inner heat
shield, remove the
two screws.
Note: If installing a vertical vent/termination off the top of
the appliance, the optional vertical termination baf e may be
needed.
Note: Use SLP Series
components only.
V
1