Hearth and Home Technologies QV36B-A Indoor Fireplace User Manual


 
Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. U • 1/12 17
5
5
Framing and Clearances
A. Selecting Appliance Location
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of traf c and away from furniture and draperies.
NOTICE: Illustrations re ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 5.1 Appliance Locations
K
C
A
L
F
I
B
G
E
D
J
J
G
A
F
C
A
H
M
N
Models A B C D
E
Min.
F
Min.
GH I JK LMN
QV32B-A
in. 42 37 59-1/2
See Section
D for Alcove
Installation
1 1/2 Min. 44 62-1/4 16-1/4 48-1/2 68-3/4 15-1/16 7-1/2 7-1/8
mm 1066 940 1511 25 13 1117 1734 413 1231 1746 383 191 181
QV36B-A
in. 45-1/2 42 64-3/8 1 1/2 45-1/2 64-3/8 16-1/4 48-1/2 68-3/4 16-5/8 7-1/2 9
mm 1155 1067 1635 25 13 1321 1861 413 1231 1746 422 191 229