D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as speci ed. Framing or nishing material closer than
the minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc).
Figure 5.3 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles
Combustible Mantels
Combustible Mantel Legs or Wall Projections
1/2 in.
SHEETROCK
3-1/2 in.
1/2 in.
AIR SPACE
NON-COMBUSTIBLE
BOARD SHIPPED
WITH APPLIANCE
Figure 5.6 Non-Combustible Zone
5
6
7
8
9
10
3
4
5
12
11
10
9
8
7
6
TOP OF HOOD OR FIREPLACE OPENING
4
12
13
11
32
CEILING
All measurements are in inches.
3 FT. MAXIMUM
TOP VIEW
5-3/8 IN.
MINIMUM
3 IN.
MINIMUM
Note: Clearance from opening
to perpendicular wall.
Figure 5.4 Clearances to Mantel Legs or Wall Projections
(Acceptable on both sides of opening.)
UNLIMITED
TOP VIEW
5-3/8 IN.
MINIMUM
3 IN.
MINIMUM
Note: Clearance from opening
to perpendicular wall.
Figure 5.5 Wall Projection (Acceptable on one side of opening.)