Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. U • 1/1252
A. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as speci ed. Framing closer than the minimums list-
ed must be constructed entirely of noncombustible materials
(i.e., steel studs, concrete board, etc.).
Figure 13.1 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles
Combustible Mantels
Combustible Mantel Legs or Wall Projections
1/2 in.
SHEETROCK
3-1/2 in.
1/2 in.
AIR SPACE
NON-COMBUSTIBLE
BOARD SHIPPED
WITH APPLIANCE
Figure 13.4 Non-Combustible Zone
5
6
7
8
9
10
3
4
5
12
11
10
9
8
7
6
TOP OF HOOD OR FIREPLACE OPENING
4
12
13
11
32
CEILING
All measurements are in inches.
3 FT. MAXIMUM
TOP VIEW
5-3/8 IN.
MINIMUM
3 IN.
MINIMUM
Note: Clearance from opening
to perpendicular wall.
Figure 13.2 Clearances to Mantel Legs or Wall Projections
(Acceptable on both sides of opening.)
UNLIMITED
TOP VIEW
5-3/8 IN.
MINIMUM
3 IN.
MINIMUM
Note: Clearance from opening
to perpendicular wall.
Figure 13.3 Wall Projection (Acceptable on one side of opening.)
13
13
Finishing