Hearth and Home Technologies QV36B-A Indoor Fireplace User Manual


 
Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. U • 1/12 25
Figure 7.5
Top Vent - Horizontal Termination
Venting with 2 elbows (NG)
Top Vent - Horizontal Termination
Venting with 2 elbows (Propane)
Note: There MUST be a 25%
reduction in total H when
using ex vent except when
using the simple up and out
installation (see Figure 5.3).
Note: Use SLP Series
components only.
V
1
Minimum H
1
+ H
2
Maximum
90 Elbow 0 ft. 0 mm
1/2 ft. 152 mm 1 ft. 305 mm
1-1/2 ft. 457 mm 2 ft. 610 mm
2-1/2 ft. 762 mm 4 ft. 1.2 m
3-1/2 ft. 1.1 m 6 ft. 1.8 m
4-1/2 ft. 1.4 m 14 ft. 4.3 m
H
1
+ H
2
MAX. =14 ft. (4.3 m)
V + H
1
+ H
2
MAX. = 40 ft. (12.2 m)
V
1
Minimum H
1
+ H
2
Maximum
90 Elbow Not Allowed
1/2 ft. 152 mm 0 ft. 0 mm
1-1/2 ft. 457 mm 2 ft. 610 mm
2-1/2 ft. 762 mm 4 ft. 1.2 m
3-1/2 ft. 1.1 m 6 ft. 1.8 m
4-1/2 ft. 1.4 m 14 ft. 4.3 m
H
1
+ H
2
MAX. =14 ft. (4.3 m)
V + H
1
+ H
2
MAX. = 40 ft. (12.2 m)
INSTALLED
HORIZONTALLY
H
1
H
2
V
1