Figure 7.10
Top Vent - Vertical Termination
Venting with 3 elbows (NG)
Top Vent - Vertical Termination
Venting with 3 elbows (Propane)
Note: There MUST be a 25%
reduction in total H when
using ex vent except when
using the simple up and out
installation (see Figure 5.3).
Note: Use SLP Series
components only.
V
1
Minimum H
1
Maximum V
2
V
1
+ V
2
Minimum
90 Elbow 0 ft. 305 mm * *
1/2 ft. 152 mm 2 ft. 610 mm * *
1-1/2 ft. 457 mm 3 ft. 914 mm * *
2-1/2 ft. 762 mm 5 ft. 1.5 m * *
3-1/2 ft. 1.1 m 7 ft. 2.1 m * *
4-1/2 ft. 1.4 m 15 ft. 4.6 m * *
H MAX. =15 ft. (4.6 m)
V
1
+ V
2
+ H
1
MAX. = 40 ft. (12.2 m)
* No speci c restrictions on this value EXCEPT V
1
+ V
2
+ H
1
+ H
2
cannot exceed 40 ft. (12.2 m)
V
1
Minimum H
1
Maximum V
2
V
1
+ V
2
Minimum
90 Elbow Not Allowed * *
1/2 ft. 152 mm 1 ft. 305 mm * *
1-1/2 ft. 457 mm 3 ft. 914 mm * *
2-1/2 ft. 762 mm 5 ft. 1.5 m * *
3-1/2 ft. 1.1 m 7 ft. 2.1 m * *
4-1/2 ft. 1.4 m 15 ft. 4.6 m * *
H MAX. =15 ft. (4.6 m)
V
1
+ V
2
+ H
1
MAX. = 40 ft. (12.2 m)
* No speci c restrictions on this value EXCEPT V
1
+ V
2
+ H
1
+ H
2
cannot exceed 40 ft. (12.2 m)
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
V
2