Page 50
Heat & Glo • NorthStar EPA Fireplace • 480-1081C
September 1, 2008
September 1, 2008
September 1, 2008
INCORRECT POSITIONS
CeramicBlanketandBafeBoardareNOTin
contactwiththebackoftherebox.
Ceramic Blanket is NOT in contact with the
backofthereboxandNOTevenwiththeBaf
-
eBoardinthefront.
Ceramic Blanket is bunched up at the back of
thereboxandNOTevenwiththeBafeBoard
in the front.
Ceramic Blanket
Back of Firebox
Baffle Board
Figure 50.2
CORRECT POSITION
Fireboxdamageduetoimproperbafeplace-
ment is not covered by warranty. Operatethe
woodburningappliancewiththebafeinthe
correct position only.
Notdoingsocouldresultin:
• Reducedefciency
• Overheatingthechimney
• Overheatingtherearoftherebox
• Poor performance
WARNING
Fire Risk
Ensurecorrectbafeplacementandreplacebafecom
-
ponents if damaged or missing.
K. Correct Bafe & Blanket Placement
CeramicBlanketandBafeBoardMUSTbe
in contact with the back of the rebox and
even with each other in the front.
Ceramic Blanket
Back of Firebox
Baffle Board
Figure 50.1