Risk of Smoke Spillage
Outsideair inlet mustbelocated to preventblockage
from:
• Leaves
• Snow/ice
• Otherdebris
Blockage may cause combustion air starvation.
CAUTION
Fire Risk
Asphyxiation Risk
Donotdrawoutsidecombustionairfrom:
• Wall,oororceilingcavity.
• Enclosed space such as an attic or
garage.
• Close proximity to exhaust vents or
chimneys.
Fumes or odor may result.
WARNING
Figure 16.1 Outside Air Inlet Locations
Attic insulation shield
must be used to keep
insulation away from
chimney.
Ceiling firestop
on floor of attic.
3 ft. (91cm) min. from top of
uppermost chimney
section to air inlet.
Handle Left - Closed
Handle Right - Open
Figure 16.2 Locating the Outside Air Control