Hearth and Home Technologies NorthStar-BK Indoor Fireplace User Manual


 
Page 32
Heat & Glo • NorthStar EPA Fireplace • 480-1081C
September 1, 2008
September 1, 2008
September 1, 2008
This kit is tested and safe when installed in accordance with
this installation manual. It is your responsibility to read all
instructions before starting installation and to follow these
instructions carefully during installations.
Installation of this kit MUST byperformedbyaqualiedser-
vice technician.
The Heat-Zone-Wood kit is carefully engineered and must
beinstalledonlyasspecied.Ifyoumodifyitoranyofits
components you will void the warranty and you may possibly
causearehazard.Installationmustbedoneaccordingto
applicablelocal,state,provincialand/ornationalcodes.
Planthelocationofthereplaceandwarmairductrun(s).
D. Heat Zone Kit
Ceiling Register
Wall Register
Floor Register
Two Duct Kits
Ceiling Register
12 in. (305mm) minimum clearance
from register to ceiling
Possible Air Duct Runs / Locations
DUCT RUN REqUIREMENTS
MAXIMUMDuctRun=40ft.(12m)
MINIMUMDuctRun=36in.(914mm)
DUCTING MATERIAL
6in.(152mm)B-VentOnly
DONOTDUCTintoexistingfurnaceplenum
MINIMUM CLEARANCE TO COMBUSTIBLES
1 in. (25mm) from the B-Vent
1
/2in.(13mm)fromtop&bottomofoutletbox
0 in. (0mm) from the sides of outlet box
12 in. (305mm) from wall register to ceiling*
*(See Figure 32.1).
CAUTION
ALLwiringshouldbedonebyaqualiedelectricianand
shall be in compliance with local codes and with the National
ElectricCodeNFPA/NEC No. 70-current(inthe United
States), or with the current CSC22.1 Canadian Electric
Code (in Canada).
Figure 32.1 Minimum Clearances to Combustibles