Hearth and Home Technologies NDV3630I Indoor Fireplace User Manual


 
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 9
D. Clear Space
WARNING! DO NOT place combustible objects in front of
the replace or block louvers. High temperatures may start
a re. See Figure 2.2.
Avoid placing candles and other heat-sensitive objects on
mantel or hearth. Heat may damage these objects.
Figure 2.2 Clear Space
C. Fan Kit (optional)
Refer to Figure 2.1 for location of control.
F. Fixed Glass Assembly
See Section 14.K.
E. Decorative Doors and Fronts
WARNING! Risk of Fire! Install ONLY doors or fronts
approved by Hearth & Home Technologies. Unapproved
doors or fronts may cause appliance to overheat.
This appliance has been supplied with an integral barrier
to prevent direct contact with the xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install
one.
For more information refer to the instructions supplied with
your decorative door or front.
G. Remote Controls, Wall Controls and Wall
Switches
Follow the instructions supplied with the control installed to
operate your replace:
For safety:
Install a switch lock or a wall/remote control with child
protection lockout feature.
Keep remote controls out of reach of children.
See your dealer if you have questions.
CLEAR SPACE
3 FT
. IN FR
ONT OF F
IRE
PLA
CE
H. Before Lighting Fireplace
Before operating this replace for the rst time, have a
quali ed technician:
Verify all shipping materials have been removed from
inside and/or underneath the rebox.
Review proper placement of logs, ember material and/or
other decorative materials.
Check the wiring.
Check the air shutter adjustment.
Ensure that there are no gas leaks.
Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire/Asphyxiation! DO NOT operate
replace with xed glass assembly removed.
Determine if this replace has a standing pilot or an
Intelli re ignition system. Ask your dealer or open control
access panel, look at valve assembly.
A standing pilot ignition will have a red or black ignitor
button (refer to Figure 2.3).
• An Intelli re ignition system will not have a button.
Red or Black
Button
Figure 2.3 Ignitor Button