Hearth and Home Technologies NDV3630I Indoor Fireplace User Manual


 
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/08 27
2. Top Vent - Vertical Termination
No Elbow
Figure 7.7a
12 ft (3.66 m) min.
60 ft (18.29 m) max.
Maximum horizontal
run is 100% of
vertical, but cannot
exceed 26 ft (7.92 m)
Figure 7.8
Two Elbows
12 ft (3.66 m) min.
60 ft (18.29 m) max.
Figure 7.7b Remove Flue Visor
Figure 7.7c 12 to 30 ft Vertical Run
Figure 7.7d 31 ft to 60 ft Vertical Run
Install Top Vent Flue Visor - No Elbow Con gura-
tions
Remove screws holding ue visor to rebox top. See Figure
7.7b.
• Remove the ue visor.
Using the screws removed and the same holes, install the
top vent ue baf e and ue visor.
- The ue visor will be turned to install below the level
of the rebox top for 12-30 ft vertical runs of vent. See
Figure 7.7c.
- The ue visor will be turned to install inside the ue for
vertical vent runs of 31-60 ft. See Figure 7.7d.
Î