Hearth and Home Technologies NDV3630I Indoor Fireplace User Manual


 
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/0850
Red or Black
Button
Figure 12.1 Ignitor Button
B. Standing Pilot Ignition System Wiring
The standing pilot ignition system wiring does not require
a 110 VAC supply to operate.
A 110 VAC junction box MUST be installed for use with
a fan or remote control. See Figure 12.3 for junction box
wiring. Keep wire lengths short as possible.
NOTICE: DO NOT wire 110 VAC to the millivolt valve! This
will damage the valve.
If using a thermostat use one compatible with a millivolt
gas valve system:
- Install the thermostat in the location as indicated in the
thermostat instructions to ensure proper operation of
appliance.
- Use low resistance thermostat wire for wiring from
ignition system to the wall switch and thermostat.
- Keep wire lengths short as possible.
12
12
Electrical Information
A. Wiring Requirements
NOTICE: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA
70-latest edition or the Canadian Electric Code
CSA C22.1.
Wire the appliance junction box to 110-120 VAC. This is
required for use of optional accessories (standing pilot
ignition) or proper operation of the appliance (Intelli re
ignition).
Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT wire
110V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.
Determine if the appliance uses an Intelli re ignition
system or standing pilot ignition system.
Open the control access panel.
A red or black ignitor button (as shown in Figure 12.1)
indicates this appliance is standing pilot ignition.
C. Intelli re Ignition System Wiring
Wire the appliance junction box to 110 VAC for proper
operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
Refer to Figure 12.2, Intelli re Pilot Ignition (IPI) Wiring
Diagram.
This appliance is equipped with an Intelli re control valve
which operates on a 3 volt system.
Plug the 3-volt AC transformer into the appliance junction
box to supply power to the unit OR install two D cell
batteries (not included) into the battery pack before use.
NOTICE: Batteries should not be placed in the battery pack
while using the transformer. Remove batteries before using
the transformer, and unplug the transformer before installing
the batteries. Battery polarity must be correct or module
damage will occur.
D. Optional Accessories Requirements
This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.