Hearth and Home Technologies NDV3630I Indoor Fireplace User Manual


 
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/0814
Venting
Frequency: Seasonally
By: Homeowner
Tools needed: Protective gloves and safety glasses.
Inspect venting and termination cap for blockage or
obstruction such plants, bird nests, leaves, snow, debris,
etc.
Verify termination cap clearance to subsequent construc-
tion (building additions, decks, fences, or sheds). See
Section 6.
Inspect for corrosion or separation.
Verify weather stripping, sealing and ashing remains
intact.
Inspect draft shield to verify it is not damaged or missing.
B. Maintenance Tasks-Service Technician
The following tasks must be performed by a quali ed tech-
nician.
Gasket Seal and Glass Assembly Inspection
Frequency: Annually
By: Service Technician
Tools needed: Protective gloves, drop cloth and a stable
work surface.
Inspect gasket seal and its condition.
• Inspect xed glass assembly for scratches and nicks that
can lead to breakage when exposed to heat.
• Con rm there is no damage to glass or glass frame.
Replace as necessary.
• Verify that xed glass assembly is properly retained and
attachment components are intact and not damaged.
Replace as necessary.
Logs
Frequency: Annually
By: Service Technician
Tools needed: Protective gloves.
Inspect for damaged or missing logs. Replace as necessary.
Refer to Section 14 for log placement instructions.
Verify correct log placement and no ame impingement
causing sooting. Correct as necessary.
Firebox
Frequency: Annually
By: Service Technician
Tools needed: Protective gloves, sandpaper, steel wool,
cloths, mineral spirits, primer and touch-up paint.
Inspect for paint condition, warped surfaces, corrosion
or perforation. Sand and repaint as necessary.
Replace appliance if rebox has been perforated.
Control Compartment and Firebox Top
Frequency: Annually
By: Service Technician
Tools needed: Protective gloves, vacuum cleaner, dust
cloths
Vacuum and wipe out dust, cobwebs, debris or pet hair.
Use caution when cleaning these areas. Screw tips that
have penetrated the sheet metal are sharp and should
be avoided.
Remove all foreign objects.
Verify unobstructed air circulation.
Burner Ignition and Operation
Frequency: Annually
By: Service Technician
Tools needed: Protective gloves, vacuum cleaner, whisk
broom, ashlight, voltmeter, indexed drill bit set, and a
manometer.
Verify burner is properly secured and aligned with pilot
or igniter.
Clean off burner top, inspect for plugged ports, corrosion
or deterioration. Replace burner if necessary.
Replace ember materials with new dime-size pieces.
DO NOT block ports or obstruct lighting paths. Refer to
Section 14 for proper ember placement.
Verify batteries have been removed from battery back-
up IPI systems to prevent premature battery failure or
leaking.
Check for smooth lighting and ignition carryover to all
ports. Verify that there is no ignition delay.
Inspect for lifting or other ame problems.
Verify air shutter setting is correct. See Section 14.N. for
required air shutter setting. Verify air shutter is clear of
dust and debris.
• Inspect ori ce for soot, dirt and corrosion. Verify ori ce
size is correct. See Service Parts List for proper ori ce
sizing.
Verify manifold and inlet pressures. Adjust regulator as
required.
• Inspect pilot ame pattern and strength. See Figures 3.1
and 3.2 for proper pilot ame pattern. Clean or replace
ori ce spud as necessary.
Inspect thermocouple/thermopile or IPI ame sensing rod
for soot, corrosion and deterioration. Clean with emery
cloth or replace as required.
Verify thermocouple/thermopile or IPI millivolt output.