Hearth and Home Technologies NDV3630I Indoor Fireplace User Manual


 
Heatilator • Novus NDV Series • 4055-187 Rev F • 06/086
B. Tempered Glass Speci cations
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous loca-
tions such as bathtub enclosures as de ned by the Con-
sumer Product Safety Commission (CPSC). The tempered
glass has been tested and certi ed to the requirements of
ANSI Z97.1 and CPSC 16 CFR 1202 (Safety Glazing Certi-
cation Council SGCC# 1595 and 1597. Architectural Test-
ing, Inc. Reports 02-31919.01 and 02-31917.01).
This statement is in compliance with CPSC 16 CFR Sec-
tion 1201.5 “Certi cation and labeling requirements” which
refers to 15 U.S. Code (USC) 2063 stating “…Such cer-
ti cate shall accompany the product or shall otherwise be
furnished to any distributor or retailer to whom the product
is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
C. BTU Speci cations
MODELS: NDV3630, NDV3933, NDV4236, NDV4842,
NDV3630I, NDV3933I, NDV4236I, NDV4842I,
NDV3630L, NDV3933L, NDV4236L, NDV4842L,
NDV3630IL, NDV3933IL, NDV4236IL, NDV4842IL
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Gas Appliance
STANDARD: ANSI Z21.88a-2007/CSA 2.33a-2007,
CGA 2.17-M91, UL 307B
This product is listed to ANSI standards for “Vented Gas
Appliance Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and Rec-
reational Vehicles”, and “Gas Fired Appliances for Use at
High Altitudes”.
A. Appliance Certi cation
E. Non-Combustible Materials Speci cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136, Stan-
dard Test Method for Behavior of Materials in a Vertical
Tube Furnace at 750 ºC and UL763 shall be considered
non-combustible materials.
F. Combustible Materials Speci cation
Materials made of or surfaced with wood, compressed pa-
per, plant bers, plastics, or other material that can ignite
and burn, whether ame proofed or not, or plastered or un-
plastered shall be considered combustible materials.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemental
room heat or as a decorative appliance. It should not be fac-
tored as primary heat in residential heating calculations.
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility or
authorities having jurisdiction.
When installing above 2000 feet elevation:
In the USA: Reduce burner ori ce 4% for each 1000 feet
above 2000 feet.
In CANADA: Reduce burner ori ce 10% for elevations
between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
1
1
Listing and Code Approvals
Novus NDV NDV3630 NDV3933
Standing Pilot or IPI
Max/Min Input Rate (NG) 20,000/14,000 22,000/15,000
Ori ce Size (NG) 0.083 0.089/#43
Max/Min Input Rate (LP) 20,000/15,000 22,000/15,000
Ori ce Size (LP) 0.053 0.055/#54
Novus NDV NDV4236 NDV4842
Standing Pilot or IPI
Max/Min Input Rate (NG) 25,000/17,000 30,000/20,500
Ori ce Size (NG) 0.093/#42 0.104/#37
Max/Min Input Rate (LP) 25,000/17,000 30,000/20,500
Ori ce Size (LP) 0.058 0.063/#52